Inloggen Inloggen
Uitgebreid Zoeken zoeken

APC SY96K96H UPS 96 kVA 96000 W

Symmetra PX 96kW Scalable, 400V € 71.095,81 incl. btw € 58.756,87 excl. btw APC

APC

Favorieten E-mail Afdrukken + - Bestel
APC - APC SY96K96H UPS 96 kVA 96000 W
Productinformatie
Categorie UPS
Voorraad 0
Levertijdsindicatie Neem contact op met afdeling sales
Artikelnummer

SY96K96H

Documentatie
Generated PDF
Beschrijving
APC SY96K96H. Output power capacity: 96 kVA, Uitgangsvermogen: 96000 W. Batterijtechnologie: Sealed Lead Acid (VRLA), Accu/Batterij oplaadtijd: 3,50 uur. Kleur van het product: Zwart, Certificering: CE,EN 50091-1,EN/IEC 62040-3,EN/IEC 62040-1-1,FCC Part 15 A,VFI-SS-111. Breedte: 1200 mm, Diepte: 1070 mm, Hoogte: 1991 mm. Type batterij: VRLA, Interface: SmartSlot, Output-aansluitingen: 1x Hard Wire 5-wire (3PH + N + G)

Audible alarms
Provide notification of changing flywheel conditions

InfraStruXure Central compatible
Enables centralized management via APC InfraStruXure® Central.

Modular design
Increases adaptability with an open architecture configurable to any IT environment.

Modular design
Modular construction - can be deployed as a non-standby and migrate to a standby (UPS) system.

LCD display
Alpha-Numeric Display which displays system parameters and alarms.

SmartSlot
Customize UPS capabilities with management cards.

Hot-swappable batteries
Ensures clean, uninterrupted power to protected equipment while batteries are being replaced

Generator compatible
Ensures clean, uninterrupted power to protected equipment when generator power is used.

Configurable for N+1 internal redundancy
Provides high availabilty through redundancy by allowing configuration with one more Power Module than is necessary to support the connected load.

Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.

Battery modules connected in parallel
Delivers higher availability through redundant batteries.

Automatic internal bypass
Supplies utility power to the connected loads in the event of a UPS overload condition or fault.
Audible alarms

Provides notification of changing utility power and UPS conditions.
User-replaceable batteries
Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)

Temperature-compensated battery charging
Prolongs battery life by regulating the charge voltage according to battery temperature.

Garantie: 1 year
Meest verkocht Grid List